برای تماس کلیک کنید

به وب سایت سما تشخیص آریا خوش آمدید.

جستجوی پیشرفته
جستجوی عینی کلمه
جستجو در محتوا
جستجو در عنوان
دنبال محصول یا مطلبی میگردید؟ در این کادر جستجو کنید

کیت های تشخیص

در حال نمایش 4 نتیجه

فیلتر ها
  • MASTER DUAL STAINING KIT
    Dual Staining

    MASTER DUAL STAINING KIT

    امتیاز 0 از 5
    اطلاعات بیشتر

    Available Size : 100 test

    Intended Use : Diagnostic in vitro in humans

    Description: Master Dual Staining Kit contains reagents to perform manual or automated immunohistoquemical dual
    staining on human tissue sections, fixed in buffered formalin and embedded in paraffin.
    This kit contains a visualization system based on micropolymers and is sufficient to perform 100 determinations
    following the recommended protocol.

    Limitations Of The Reactives
    The use on frozen tissue has not been evaluated.
    In order to use the Master Dual Staining kit it should be noted that the two antibodies must come from different
    animals (mouse / rabbit).
    Due to the presence of a soluble chromogen in alcoholic solutions, the slides must be air-dried and for final mounting
    an aqueous mounting media should be used.

  • MASTER POLYMER PLUS ALKALINE PHOSPHATASE DETECTION SYSTEM
    AP

    MASTER POLYMER PLUS ALKALINE PHOSPHATASE DETECTION SYSTEM

    امتیاز 0 از 5
    اطلاعات بیشتر

     Available Size : 100 test / 500 test

    Kit components:
    DAB Substrate Buffer (READY-TO-USE)
    DAB Chromogen Concentrate (READY-TO-USE)
    DAB enhancer (READY-TO-USE)

    Master Polymer Plus AP is the result of the experience of a decade in systems of polymers for
    immunohistochemistry. The detection system has proven greater sensitivity with an increase in the antigenantibody
    binding signal. The new technology of micropolymers provides greater advantages as compared to
    the conventional immunohistochemistry techniques and facilitates the detection of antigens in the different
    cellular compartments (nucleus, cytoplasm, cytoplasmic membrane) due to the smaller size of the molecule.
    The technical procedure used eliminates the background staining originated by the non-specific binding to
    endogenous biotin molecules, as Master Polymer Plus AP is a procedure not based in the reaction
    avidin/biotin.
    The detection system Master Polymer Plus AP is highly sensitive, provides a low background staining and
    the results obtained are higher than the ones obtained with the conventional procedures of
    Streptavidin/Biotin or long polymers.
    The system Master Polymer Plus AP is elaborated with the technology of micropolymers.
    This system can be used with:
    – Monoclonal primary antibodies obtained in mouse.
    – Monoclonal and polyclonal primary antibodies obtained in rabbit.

  • Bcl-2 Monoclonal Antibody
    DAB

    Immunoperoxidase DAB Kit (Dark Brown)

    امتیاز 0 از 5
    اطلاعات بیشتر

    Available Size : 100 test / 500 test

    Kit components:
    DAB Substrate Buffer (READY-TO-USE)
    DAB Chromogen Concentrate (READY-TO-USE)
    DAB enhancer (READY-TO-USE)

    Spcificity, Interferences and Limitations:
    The Immunoperoxidase DAB Kit (Dark Brown) is preferred for immunohistochemical staining methods, based
    on peroxidase marked antibodies and in situ hybridization.
    Once the DAB oxidation has occurred, a brown insoluble precipitate is obtained. An increase or decrease in the
    ratio between the chromogen and its substrate volumes, as well as exposure to bright light, can affect the
    degree of specific staining and background of the final reaction. For this reason it is recommended that the
    staining should be made in low light conditions.

  • ALK (Anaplastic Lymphoma Kinase)
    DAB

    Master Polymer Plus Detection System (Peroxidase)

    امتیاز 0 از 5
    اطلاعات بیشتر

    Available Size : 100 test / 500 test / 1250 test

    Intended use: Product for in vitro diagnostic use.

    Master Polymer Plus Detection System is developed based on the micro-polymer technology and is the result of a decade of experience in polymer systems for immunohistochemistry. This detection system has demonstrated higher sensitivity with an increase in the antigen-antibody binding signal. The novel technology of micro-polymers provides greater advantages than conventional immunohistochemical techniques and facilitates the detection of antigens in different cellular compartments (nucleus, cytoplasm and cell membrane) due to the smaller size of the molecule. It also eliminates background staining caused by nonspecific binding of endogenous biotin molecules as the Master Polymer Plus Detection System staining procedure is not based on the avidin / biotin reaction.

    – Primary monoclonal and polyclonal antibodies obtained in mouse
    – Primary monoclonal and polyclonal antibodies obtained in rabbit.

اسکرول به بالا